Measurement of Unknown Capacitance and Resistance Using Wein's Bridge.

STEP 1 : Make Connections as per the instructions given below:

1.    M1 of MCB - P1 of Power and M2 of MCB - P2 of Power

2.    A1 of Amplitude - A3 of Circuit Diagram and A2 of Amplitude - A4 of Circuit Diagram

3.    D1 of Digital Null Detector - B of Circuit Diagram

4.    D2 of Digital Null Detector - D of Circuit Diagram

5.    COM - C of Circuit Diagram

6.    CX - D of Circuit Diagram

NOTE : If wire is wrongly connected, Click on node number to detach the wire.

STEP 2 : Click on   CHECK  button for checking the connections.

STEP 3 : Click on the mcb off MCB to Turn ON mcb on the supply.

STEP 4 : Set Amplitude to maximum from dropdown.

STEP 5 : Select the resistance values from various dropdown to get minimum value from digital null detector.

STEP 6 : Click on   ADD  button to add the readings to the Observation Table.

NOTE : If combination is wrong then select another combination.

STEP 7 : Add different readings to the table by selecting different values from dropdown.

STEP 8 : Click on   PRINT  button to print the webpage.

STEP 9 : Click on   RESET  button to refresh the webpage.