Three Phase Half Wave Silicon Controlled Rectifier with R Load and RL Load

Three Phase Half Wave SCR with R Load

STEP 1: Drag and drop the components in the workspace to create the circuit.

Nos of required components:

AC Source – 3, Thyristor – 3, Gate Pulse - 3, Resistor - 1

Voltmeter – 10, Ammeter - 1, Ground – 4


STEP 2: Make the connections as per the instructions given below:

(a) (01-12, 12-25, 02-03, 03-06, 04-07, 05-08)

(b) (08-09, 10-11, 04-23, 24-43, 13-14, 14-17)

(c) (15-18, 15-23, 16-19, 19-20, 21-22, 26-36)

(d) (34-36, 35-37, 37-23, 02-27, 13-29, 26-31)

(e) (25-33, 28-33, 30-33, 32-33, 38-39, 39-40)

(f) (41-42, 44-32, 24-45, 46-32)

Note: Click on the wire to delete the connection.

STEP 3: Click on the CHECK button to check the connections.

Note: Right click on the component to open the dialog box to edit the properties of the component.

STEP 4: Input the values for all the required components (AC Sources, Gate Pulses and Resistor) and the waveform will get plot automatically.

STEP 5: Now, Click on the ADD button to insert the reading into the observation table.

STEP 6: Now, you can input different values as per your requirement to get the desired waveform.

STEP 7: Repeat Step 5 to again insert the reading into the table and now repeat Steps 6 to 7 to take more readings.

STEP 8: Click on the PRINT button to take out the print of the webpage.

STEP 9: Click on the RESET button to reload the webpage.

Three Phase Half Wave SCR with RL Load

STEP 1: Drag and drop the components in the workspace to create the circuit.

Nos of required components:

AC Source – 3, Thyristor – 3, Gate Pulse - 3, Resistor - 1

Inductor - 1, Voltmeter – 10, Ammeter - 1, Ground – 4


STEP 2: Make the connections as per the instructions given below:

(a) (01-12, 12-25, 02-03, 03-06, 04-07, 05-08)

(b) (08-09, 10-11, 04-23, 24-43, 13-14, 14-17)

(c) (15-18, 15-23, 16-19, 19-20, 21-22, 26-36)

(d) (34-36, 35-37, 37-23, 02-27, 13-29, 26-31)

(e) (25-33, 28-33, 30-33, 32-33, 38-39, 39-40)

(f) (41-42, 44-47, 48-32, 24-45, 46-32)

Note: Click on the wire to delete the connection.

STEP 3: Click on the CHECK button to check the connections.

Note: Right click on the component to open the dialog box to edit the properties of the component.

STEP 4: Input the values for all the required components (AC Sources, Gate Pulse 1, Resistor and Inductor) and the waveform will get plot automatically.

STEP 5: Now, Click on the ADD button to insert the reading into the observation table.

STEP 6: Now, you can input different values as per your requirement to get the desired waveform.

STEP 7: Repeat Step 5 to again insert the reading into the table and now repeat Steps 6 to 7 to take more readings.

STEP 8: Click on the PRINT button to take out the print of the webpage.

STEP 9: Click on the RESET button to reload the webpage.