Single Phase Half Wave Silicon Controlled Rectifier with R Load, RL Load & RLE Load
Single Phase Half Wave SCR with R Load
Nos of required components:
AC Source – 1, Thyristor - 1, Gate Pulse - 1, Resistor - 1
Ammeter - 1, Voltmeter – 4, Ground – 1
STEP 2: Make the connections as per the instructions given below:
(a) (01-05, 03-05, 08-05, 09-06)
(b) (02-17, 04-17, 07-10)
(c) (10-11, 12-13, 06-14)
(d) (06-18, 15-16, 17-19)
Note: Click on the wire to delete the connection.
STEP 3: Click on the CHECK button to check the connections.
Note: Right click on the component to open the dialog box to edit the properties of the component.
STEP 4: Input the values for all the required components (AC Source, Gate Pulse and Resistor) and the waveform will get plot automatically.
STEP 5: Now, Click on the ADD button to insert the reading into the observation table.
STEP 6: Now, you can input different values as per your requirement to get the desired waveform.
STEP 7: Repeat Step 5 to again insert the reading into the table and now repeat Steps 6 to 7 to take more readings.
STEP 8: Click on the PRINT button to take out the print of the webpage.
STEP 9: Click on the RESET button to reload the webpage.
Single Phase Half Wave SCR with RL Load
STEP 1: Drag and drop the components in the workspace to create the circuit.
Nos of required components:
AC Source – 1, Thyristor - 1, Gate Pulse - 1, Resistor - 1
Inductor - 1, Ammeter - 1, Voltmeter – 4, Ground – 1
STEP 2: Make the connections as per the instructions given below:
(a) (01-05, 03-05, 08-05, 09-06)
(b) (02-21, 04-21, 07-10, 10-11)
(c) (12-13, 06-14, 15-16)
(d) (15-18, 17-20, 19-21)
Note: Click on the wire to delete the connection.
STEP 3: Click on the CHECK button to check the connections.
Note: Right click on the component to open the dialog box to edit the properties of the component.
STEP 4: Input the values for all the required components (AC Source, Gate Pulse, Resistor and Inductor) and the waveform will get plot automatically.
STEP 5: Now, Click on the ADD button to insert the reading into the observation table.
STEP 6: Now, you can input different values as per your requirement to get the desired waveform.
STEP 7: Repeat Step 5 to again insert the reading into the table and now repeat Steps 6 to 7 to take more readings.
STEP 8: Click on the PRINT button to take out the print of the webpage.
STEP 9: Click on the RESET button to reload the webpage.
Single Phase Half Wave SCR with RLE Load
STEP 1: Drag and drop the components in the workspace to create the circuit.
Nos of required components:
AC Source – 1, Thyristor - 1, Gate Pulse - 1, Resistor - 1, Inductor - 1
DC Source - 1, Ammeter - 1, Voltmeter – 5, Ground – 1
STEP 2: Make the connections as per the instructions given below:
(a) (01-05, 03-05, 08-05, 09-06, 02-23)
(b) (04-23, 07-10, 10-11, 12-13)
(c) (06-14, 15-16, 15-18, 17-20)
(d) (21-22, 22-24, 19-23, 23-25)
Note: Click on the wire to delete the connection.
STEP 3: Click on the CHECK button to check the connections.
Note: Right click on the component to open the dialog box to edit the properties of the component.
STEP 4: Input the values for all the required components (AC Source, Gate Pulse, Resistor, Inductor and DC Source) and the waveform will get plot automatically.
STEP 5: Now, Click on the ADD button to insert the reading into the observation table.
STEP 6: Now, you can input different values as per your requirement to get the desired waveform.
STEP 7: Repeat Step 5 to again insert the reading into the table and now repeat Steps 6 to 7 to take more readings.
STEP 8: Click on the PRINT button to take out the print of the webpage.
STEP 9: Click on the RESET button to reload the webpage.