Detection and estimation of oxidative rancidity in fats/oils
Materials Required
- Fat/oil sample
- Analytical balance
- Hot plate
- Beaker
- Burette
- Conical flasks
- Measuring cylinders
- Acetic acid-chloroform solution (3:2 ratio)
- Saturated Potassium iodide (KI) solution
- 0.1 N Sodium thiosulfate standard solution
- 1% Starch indicator solution
Methods
- Take fat/oil sample and in case of fat sample melt it by heating to its melting point using hot plate.
- Weigh 5 g of sample in a conical flask.
- Add 30 ml of acetic acid- chloroform solution in the sample flask.
- Add 0.5 ml saturated KI solution and shake it for 1 min.
- Then add 30 ml distilled water to the sample conical flask.
- Titrate the mixture against 0.1 N sodium thiosulphate solution until yellow color is almost disappeared.
- Add 0.5 ml of 1% starch solution shake vigorously
- Titrate again carefully till the blue color just disappears.
- Record the volume of sodium thiosulphate solution used.
- Calculate the peroxide value using the equation given below:
Where,
S= volume of sodium thiosulphate used (ml)
N= Normality of sodium thiosulphate
W= weight of sample (gm)
- Estimate oxidative rancidity of sample on the basis of determined peroxide value.