Hall-Effect : Determination of carrier concentration
To display the Magnetic field vs current graph
- Select the procedure ‘magnetic field vs current’ from the menu
- Click on “Insert Hall sensor’
- Add magnetic field values displayed on the gauss meter to the table by clicking the various choice of current starting from 200mA to 500mA with a 50 mA interval
- Click on the ‘Observations’ and then click on the “I/B GRAPH” button to plot the graph of Magnetic field vs Current from the displayed observation table
- Close the graph and click on ‘Reset’ button.
For Hall effect
- Select the procedure ‘Hall effect’ from the menu.
- Click on “Insert Probe’
- Click on ‘select the material’ and choose the semiconductor material
- Add magnetic field values displayed on the gauss meter to the table by clicking the various choice of current starting from 200mA to 500mA with a 50 mA interval.
- Click on the ‘Observations’ and then click on the “Plot Graph” button to plot the graph of Hall voltage Vs Magnetic field from the displayed observation table.
- Click on the ‘Show result’ button to display the results.