Measurement of Capacitance by Schering Bridge.

STEP 1 : Make connections as per the instructions given below:

  1. M1 of MCB - M3 of Kit
  2. M2 of MCB - M4 of Kit
  3. D1 of Digital Null Detector - D3 of Circuit Diagram
  4. D2 of Digital Null Detector - D4 of Circuit Diagram
  5. X1 - S1 of Capacitor
  6. X2 - S2 of Capacitor

NOTE : If wire is wrongly connected, Click on node number to detach the wire.

STEP 2 : Click on   CHECK  button for checking the connections.

STEP 3 : Click on the mcboff MCB to Turn ON mcbon the circuit.

STEP 4 : Vary x10Ω knob by selecting the values from dropdown until you reach the minimum value of the digital null detector.

STEP 5 : Now, Vary x100Ω knob by selecting the values from dropdown until you get the minimum value of the digital null detector.

STEP 6 : Click on   ADD  button to add the readings to the Observation Table.

NOTE: If combination is wrong then select another combination & the balanced condition button becomes active after the wrong combination alert.

STEP 7 : Click on   PRINT  button to print the webpage.

STEP 8 : Click on   RESET  button to reset the webpage.