Design of RC Isolated Footing with Axial Load

Procedure

Level 1:

  • Input the Working Load (P) in kN
  • Specify the design value for concrete strength (fck) in N/mm2
  • Specify the design value for steel yield strength (fy) in N/mm2
  • Enter the column width (b) in mm
  • Provide the column depth (h) in mm
  • Input the Safe Bearing Capacity (SBC) of the soil in kN/m2
  • Enter the effective cover (d') in mm
  • Once all the basic design parameters are entered, click on "Configure" to proceed to the next level.

Level 2:

  • Calculate the following:
    • Factored Load (Pu) in kN
    • Self weight
    • Total Load (kN)
    • Area of Footing (Af) in m2
    • Length of footing (Lf) in m
    • Width of footing (Bf) in m
    • Soil Pressure (Wu) in kN/m2
  • After three incorrect attempts, the correct formula and answer will be displayed.
  • After calculation, proceed to the next level.

Level 3:

  • Calculate:
    • Mux, Muy
    • dx, dy
    • Total depth
  • After three incorrect attempts, the correct formula and answer will be displayed.
  • After calculation, proceed to the next level.

Level 4:

  • Calculate Astx
  • Select the bar diameter to be used
  • Calculate the area of one bar
  • Spacing will be calculated
  • Then calculate and enter the value of:
    • Area of steel provided
    • pt% (percentage of steel)
  • After calculation, proceed to the next level.

Level 5:

  • Similarly, calculate:
    • Asty
    • Other different parameters with conditions
    • pt%
  • After all calculations, click on "Submit"