Design of RC Isolated Footing with Axial Load
Procedure
Level 1:
- Input the Working Load (P)
- Specify the design value for concrete strength (fck)
- Specify the design value for steel yield strength (fy)
- Enter the column width (b)
- Provide the column depth (h)
- Input the Safe Bearing Capacity (SBC) of the soil
- Enter the effective cover (d')
- Once all the basic design parameters are entered, click on "Configure" to proceed
Level 2:
- Calculate self weight , Total Load (kN), Area of Footing Af (m2) ,Lf, Bf, Soil Pressure wu
- After calculation go to next Level
Level 3:
- Calculate Mux, Muy, dx, dy and total depth
- After calculation go to next Level
Level 4:
- Calculate Astx and other different parameters with conditions and then calculate ptpercent
- After calculation go to next Level
Level 5:
- Similarly,calculate Asty and other different parameters with conditions and then calculate ptpercent
- After calculation click on "Submit"