Simulator :
- Enter Working Load (P)
- Select design values for concrete strength (fck)
- Select design values for steel yield strength (fy)
- Enter size of column b.
- Enter Value of h.
- Enter Value SBC of Soil.
- Enter Value effective Cover d'
- After all basic design configurations click on forward button and go to next page for calculate the applied axial load (Pu) on the column.
- Calculate self weight , Total Load (kN), Area of Footing Af (m2) ,Lf, Bf, Mux, Muy.
- Check for bearing capacity excedance.
- Select appropriate bar diameter and spacing for the top and bottom reinforcement layers.
- Click on forward button and go to next page for footing design animation.