Design of RC Isolated Footing with Axial Load and Bending Moment

Procedure

Simulator :

  • Enter Working Load (P)
  • Select design values for concrete strength (fck)
  • Select design values for steel yield strength (fy)
  • Enter size of column b.
  • Enter Value of h.
  • Enter Value SBC of Soil.
  • Enter Value effective Cover d'
  • After all basic design configurations click on forward button and go to next page for calculate the applied axial load (Pu) on the column.
  • Calculate self weight , Total Load (kN), Area of Footing Af (m2) ,Lf, Bf, Mux, Muy.
  • Check for bearing capacity excedance.
  • Select appropriate bar diameter and spacing for the top and bottom reinforcement layers.
  • Click on forward button and go to next page for footing design animation.