Performance Characteristics of Gear Pump
Procedure –
- Ensure the complete opened position of delivery valve.
- Measure height of the pressure gauge above the vacuum gauge.
- Switch on the pump.
- Vary the flow rate (discharge) by closing the delivery valve.
- Adjust the delivery valve accordingly the pressure gauge reading of 1 kg/cm2.
- Note down vacuum gauges reading.
- Note down time taken for ‘h’ cm rise of oil (10 cm) in collecting tank.
- Note down the time taken for ‘n’ revolutions for energy meter disc (3 rev).
- Repeat the procedure for 1 kg/cm2 incremental by closing the delivery valve gradually, (i.e. 1.0, 1.5, 2.0, 2.5 and 3.0 kg/cm2).
- Switch off the power supply after opening the delivery valve completely.
Formulae –
Graph – Draw graphs of Discharge vs Head, Output Power, Efficiency.