Measurement of Capacitance by De Sauty's Modified Bridge            

At 2 MHz, the resonance is obtained with a resonating capacitance value of 12 pF and at 400 kHz, the resonance is obtained with resonating capacitance value of 320 pF. Then the self capacitance of the coil is
Explanation

Explanation

Explanation

Explanation

Explanation

Explanation

Explanation

Explanation

A De Sauty's (Modified) bridge is used to measure the capacitance of a sample of sheet chage at 2kHz. At balance, arm ab is a resistor R1=300Ω in series with a capacitor C1=0.21`uF`; arm bc is R3=600Ω; arm cd is R4=200Ω and arm da is a resistor R2=1kΩ in series with a unknown capacitor C2. Capacitor C1 has internal resistance r1=60.2Ω. Calculate the effective impedence of the unknown capacitor under test conditions.