Zeeman-Effect

Objective

    To observe Zeeman effect and to calculate Bohr magneton.

Optical rail, Electromagnet, Mercury discharge tube, Polarizer, Fabry Perot etalon, Telescope with focusing lens, CCD Camera, Constant current supply, digital Gauss meter, Zeeman effect power supply, TV monitor, Micrometer.

constantpowersupply Constant Current Supply
zeemanpowersupply Zeeman effect power supply
gauss Digital Gauss Meter
gauss Zeeman setup
hallsensor Hall Probe
hallsensor Mercury Discharge Tube


probe wire
Thickness of air gap for Etalon t = 4mm or 0.4cm
Magnetic Field H = 9.95 KGauss
Micrometer initial reading Ri = 2.07mm
No. of spectral lines splitting of spectral lines split position Rs(mm) Actual Radians R = Rs - Ri(mm) R2 (mm)2
1 a 3.18 1.11 1.232
b 3.44 1.37 1.877
c 3.67 1.60 2.561
2 a 4.15 2.08 4.326
b 4.31 2.24 5.018
c 4.40 2.33 5.429
3 a 4.74 2.67 7.136
b 4.89 2.82 7.952
c 4.99 2.92 8.526
4 a 5.30 3.23 10.433
b 5.39 3.32 11.023
c 5.45 3.38 11.425
Component Ring Number 1 2 3 4
Δ12 Δ34
a 3.094 3.297
δab 0.645 0.692 0.816 0.590
b 3.141 3.071
δbc 0.634 0.411 0.574 0.402
c 2.868 2.899
Current (A) Magnetic Field (KGauss)

Controls

Current: A