MCB
POWER
Rx
DIGITAL  NULL  DETECTOR
CIRCUIT  DIAGRAM
R1
R2
R3
Rx
C1
Cx
A
UNKNOWN  CAPACITANCE
Cx
R1
R2
R3
STEP 1 : Make Connections as per the instructions given below:
1.    M1 of MCB - P1 of Power and M2 of MCB - P2 of Power
2.    A1 of Amplitude - A3 of Circuit Diagram and A2 of Amplitude - A4 of Circuit Diagram
3.    D1 of Digital Null Detector - B of Circuit Diagram
4.    D2 of Digital Null Detector - D of Circuit Diagram
5.    COM - C of Circuit Diagram
6.    CX - D of Circuit Diagram
NOTE : If wire is wrongly connected, Click on node number to detach the wire.
STEP 2 : Click on "CHECK" Button for checking the connections.    
STEP 3 : Click on the MCB to Turn ON the supply.
STEP 4 : Set Amplitude to maximum from dropdown.
STEP 5 : Select the resistance values from various dropdown to get minimum value from digital null detector.
STEP 6 : Click on "ADD" button to add the readings to the Observation Table.
NOTE : If combination is wrong then select another combination.
STEP 7 : Add different readings to the table by selecting different values from dropdown.
STEP 8 : Click on "PRINT" button to print the webpage.
STEP 9 : Click on "RESET" button to refresh the webpage.
1.  Find Cx (Unknown Capacitance)
     Where,  Cx = (C1*R2)/R3 ,  C1 = 0.01µF
2.  Find Rx (Unknown Resistance)
     Where,  Rx = (R1*R3)/R2
S.NO. | R1(KΩ) | R2(Ω) | R3(Ω) | Rx(KΩ) | Cx(µF) |
---|