To conduct a performance test on double acting reciprocating pump.
Reciprocating Pump Setup with Motor, Collecting Tank, Spring Balance, Pressure Gauge, Stopwatch.
Start the reciprocating pump by pressing the start button.
Set the speed of motor to be constant by turning the knob.
Speed of the motor (Nm) =
Speed of the pump (Np) =
Take the delivery head reading corresponding to the discharge.
Delivery head (Hd)=
Delivery head (Hd)=
Take the suction head reading corresponding to the discharge.
Suction head (Hs)=
Suction head (Hs)=
z = 15cm
Total Head (H)=
H (m) = Hs+Hd+zCoincide pointers by turning the wheel and get spring balance reading to determine torque.
Torque reading (τ) =
τ(N-m) = S×r×gSpring balance reading (S)=
Radius of torque area (r) = 0.1m
Note the actual discharge of water in the collecting tank by closing the stopper.
Area of collecting tank (A) = 0.125m2
Time required by water to fill 10 cm height (t1)=
Actual discharge, Qact =
Qact (x 10-4m3/sec)= (A × h)⁄t1Calculate the time taken by the energy meter for 5 revolution.
Time taken by energy meter for 5 revolution =
Specific Weight of water (γ) = 9810N/m3
Time taken by energy meter for 5 revolution(t2) =
Actual discharge (Qact) =
Total head (H) =
Speed of motor (Nm) =
Speed of pump (Np) =
Torque (τ) =
Trial =