Kaplan Turbine

100 100 90 80 70 60 50 40 30 20 10 0 10 20 50 60 70 80 90 40 30 mm Hg h1 0 mm h2 0 mm 0 kg/cm^2 Pressure GaugeReading 00 mm of Hg Vaccum PressureGauge Reading Flow ControlValve Flow Opening Valve 00.00 A 00.00 V 0 RPM
Instructions

Welcome to the Simulator!
Start the Simulator by using Power On Button.

Valve Positioning

OBSERVATION

Formulaes

H = { ( P × 10 ) + ( P v × 0.0136 ) } m

Q = c d × A 1 × A 2 × 2 g h A 1 2 - A 2 2 × m 3 / uc

IP = wQH 1000   KW

OP = V × l ( η T × η A × 1000 )   KW

η = OP IP × 100%

Ns = N P H 5 4

Provided Data

Coefficient of discharge (Cd) = 0.62
Orifice diameter (d2) = 100 mm
Orifice inlet diameter (d1) = 153 mm
Tranemiuion fficiency (ηT) = 0.75
Alternate efficiency (ηA) = 0.75

Observation Table (constant Head)
S. No. N
(RPM)
P
(Kg cm2)
Pv
(mm of Hg)
Orifice Meter Head Power Output
h1
(mm of Hg)
h2
(mm of Hg)
h
(m of Water)
V
(Volts)
I
(ampere)
1.
2.
3.
4.
5.
Calculate Table
S. No. Total Head H
(m)
Q
(m^3/s)
Input Power
(kW)
Output Power
(kW x 10e-3)
Efficiency
(%)
Ns
(RPM)
1.
2.
3.
4.
5.
Observation Table (constant RPM)
S. No. N
(RPM)
P
(Kg cm2)
Pv
(mm of Hg)
Orifice Meter Head Power Output
h1
(mm of Hg)
h2
(mm of Hg)
h
(m of Water)
V
(Volts)
I
(ampere)
1.
2.
3.
4.
5.
Calculation Table
S. No. Total Head H
(m)
Q
(m3/s)
Input Power
(kW)
Output Power
(kW x 10e-3)
Efficiency
(%)
Ns
(RPM)
1.
2.
3.
4.
5.