To conduct the performance test on centrifugal pump and to plot the operating characteristics.
Centrifugal Pump Setup, Wattmeter, Tachometer, V-notch setup, Hook Gauge, Measuring Scale.
Start the pump by pressing the start button.
Description Tachometer: is a sensor device used to measure the rotation speed of an object such as the engine shaft in a car, and is usually restricted to mechanical or electrical instruments. This device indicates the revolutions per minute (RPM) performed by the object.Rotate the handle to set the speed of motor to be constant and check the speed using tachometer.
Description Total Static Head: is a term primarily used in hydraulics to denote the static pressure in a pipe, channel, or duct flow.Speed of Motor = ____ rpm
Open the delivery valve and allow the water to flow in the channel. Take the hook guage reading at the V-notch before and after valve opening to find the discharge.
Initial reading (water level till crest) = ____ cm
Final reading = ____ cm
Head of water = ____ cm
Actual discharge Qact =______m3/sec
Qact (cm3/sec) = 14.17 × h(5/2)Note the delivery pressure reading for the corresponding discharge.
Delivery Head = ____ kg/cm2
Delivery Head = ____ m
Take the suction head pressure reading corresponding to the discharge.
Suction Head = ____ kg/cm2
Suction Head = ____ m
z = 43 cm
H (m)= Hd+Hs+z
Note the watt meter reading corresponding to the discharge.
Wattmeter Reading (WR)= ____ Watt
Wattmeter Reading (WR) =
Actual Discharge (Qact) =
Total Head (H) =
Result
Input power =
Input Power (W) = WR × Wc × ηm × NpOutput power =
Output Power (W) = γ × Qact × HEfficiency =
η (%) = Output Power⁄Input Power× 100Trial =
Both ends of the pipe must be trimmed to ensure parallel faces.